OMEGAWAVE,INC.

PROBE LIST for LASER TISSUE BLOOD FLOWMETR
STYLE TYPE PURPOSE and FEATURE
Non-contact
Measurement@without
contacting a probe
ST-N General probe for non-contact measurement.
Measurement area is inside a circle having diameter
of the half of the distance between the tissue and
Measurement the probe.
The distance is about 5`30mm.
Averaged flow can be obtained because of its wide
measurement area.
Operation can be done on the measurement point.

CS-N Small Lens is attached on the incidence of ST-N. Small area can be
measured. (1mm)
Operation can be done on the measurement point.
PS-N Small prism is attached on the incidence.
Suitable when the cable of ST-N disturbs measurement.
Conventional
Probes should be in
contact with tissue
EG(EZ)Fine Two of free 0.25mm optical fibers
Flexible and multi purpose.
Probes should be Tip can be fixed on a skull using super glue.
in contact with Suitable for ischemia experiment.
tissue. Optical fibers can be cut and reused after experiment using special
tools. about 300 times. No need for repair of the tip.

Inserted into tissue using a needle guide. Skin can be measured using the
reflector.

EG(EZ) Same as EG Fine but the diameter of the optical fibers isA0.5mm.
Flexible and durable.
Skin under cloth can be measured using the reflector.

GJ + JF EG Fine probe having a small optical connector in the middle.
Main probe, GJ, and the tip, JF, is connected.
JF has the same function as EZ Fine.
JF is small and light, and it can be left on an animal.
One flowmeter, GJ and some JF allows multi point measurement.
JF can be fixed on a skull using super glue, and cut and reuse about
100 times.J

DS
Disc Shape
Prism on the tip.
10mmAthickness 2.5mm.
Double face tape is used for fixing.
Standard probe for measurement of skin blood flow.

TS
Tablet Shape
Thinner than DS.
Suitable when DS is too big.

LS Fixed by double face tape.
Incidence is at right angles to the cable.
Low attenuation of light because of no prism.

NS
Needle Shape
Needle having 0.55`1mm.
Needle Shape Suitable for narrow point.
JS With Single Fiber, suitable for chronic experiment.
Diameter of Single Fiber is0.5mm.
Single Fiber is inserted into tissue.
JS and Single Fiber is connected when measurement.

FS With Fiber Sheath, suitable for chronic experiment. Fiber sheath has
the shape of a cup having 2mm.

Fiber Sheath can be fixed on the skull of a small animal.FS and Fiber
Sheath is connected when measurement.

MF
Having 5 receiving optical fibers for wider separation of
incidence and
receiving to detect deeper area.

Measurement depth is about 2`3mm.
FLO-N1 is needed.